ppc64-diag
ela_msg.h
Go to the documentation of this file.
1 
21 #ifndef _H_RPA_ELA_MSG
22 #define _H_RPA_ELA_MSG
23 
24 #define F_POWER_SUPPLY "Power Supply"
25 
26 #define MSGCPUB12b0 "CPU internal error"
27 
28 #define MSGCPUB12b5 "Time-out error waiting for I/O"
29 
30 #define MSGCPUALLZERO "An error has been detected by the CPU. The error " \
31  "log indicates the following physical FRU location(s) as the probable "\
32  "cause(s)."
33 
34 #define MSGMEMB12b0 "Uncorrectable Memory Error"
35 #define MSGMEMB12b1 "ECC correctable error"
36 
37 #define MSGMEMB12b2 "Correctable error threshold exceeded"
38 #define MSGMEMB12b5 "Memory Data error (Bad data going to memory)"
39 #define MSGMEMB12b6 "Memory bus/switch internal error"
40 #define MSGMEMB12b7 "Memory time-out error"
41 #define MSGMEMB13b3 "I/O Host Bridge time-out error"
42 #define MSGMEMB13b4 "I/O Host Bridge address/data parity error"
43 
44 #define MSGMEMALLZERO "An error has been detected by the memory controller. " \
45  "The error log indicates the following physical FRU location(s) as the " \
46  "probable cause(s)."
47 
48 #define MSGIOB12b0 "I/O Bus Address Parity Error"
49 #define MSGIOB12b1 "I/O Bus Data Parity Error"
50 #define MSGIOB12b4 "I/O Error on ISA bus"
51 
52 #define MSGIOB12b5 "Intermediate or System Bus Address Parity Error"
53 #define MSGIOB12b6 "Intermediate or System Bus Data Parity Error"
54 #define MSGIOB12b7 "Intermediate or System Bus Time-out Error"
55 
56 #define MSGIOALLZERO "An error has been detected by the I/O. The error " \
57  "log indicates the following physical FRU location(s) as the probable " \
58  "cause(s)."
59 
60 #define MSGSPB16b0 "Time-out on communication response from Service Processor"
61 #define MSGSPB16b1 "I/O general bus error"
62 #define MSGSPB16b2 "Secondary I/O general bus error"
63 
64 #define MSGSPB16b3 "Internal Service Processor memory error"
65 #define MSGSPB16b4 "Service Processor error accessing special registers"
66 #define MSGSPB16b5 "Service Processor reports unknown communication error"
67 #define MSGSPB16b7 "Other internal Service Processor hardware error"
68 #define MSGSPB17b0 "Service Processor error accessing Vital Product Data EEPROM"
69 #define MSGSPB17b1 "Service Processor error accessing Operator Panel"
70 #define MSGSPB17b2 "Service Processor error accessing Power Controller"
71 #define MSGSPB17b3 "Service Processor error accessing Fan Sensor"
72 #define MSGSPB17b4 "Service Processor error accessing Thermal Sensor"
73 #define MSGSPB17b5 "Service Processor error accessing Voltage Sensor"
74 #define MSGSPB18b0 "Service Processor error accessing serial port"
75 #define MSGSPB18b2 "Service Processor error accessing " \
76  "Real-Time Clock/Time-of-day clock"
77 
78 #define MSGSPB18b4 "Service Processor detects loss of voltage from the battery"
79 
80 #define MSGXEPOW1n11 "Fan is turning slower than expected"
81 #define MSGXEPOW1n64 "Fan stop was detected"
82 #define MSGXEPOW2n32 "Over voltage condition was detected"
83 #define MSGXEPOW2n52 "Under voltage condition was detected"
84 #define MSGXEPOW3n21 "Over temperature condition was detected"
85 #define MSGXEPOW3n73 "System shutdown due to over maximum temperature condition"
86 
87 #define MSGEPOWB1505 "System shutdown due to: 1) Loss of AC power,\n " \
88  "2) Power button was pushed without proper system\n" \
89  "shutdown, 3) Power supply failure."
90 
91 #define MSG_UNSUPPORTED_MEM "Uncorrectable memory or unsupported memory"
92 #define MSG_MISSING_MEM "Missing or bad memory"
93 #define MSG_BAD_L2 "Bad L2 Cache"
94 #define MSG_MISSING_L2 "Missing L2 cache"
95 
96 #define MSGMENUG102 "651102 "\
97  "A non-critical system cooling problem has been detected.\n" \
98  "The system temperature appears to be above the expected range.\n"\
99  "Check for elevated room temperatures, restricted air flow\n"\
100  "around the system or any system covers that are opened.\n"\
101  "If no problem is found, contact your service provider."
102 
103 #define MSGIOB13b4 "I/O Expansion Bus Parity Error."
104 #define MSGIOB13b5 "I/O Expansion Bus Time-out Error."
105 #define MSGIOB13b6 "I/O Expansion Bus Connection Failure."
106 #define MSGIOB13b7 "I/O Expansion Unit not in an operating state."
107 
108 #define MSGEPOWPCI111 "System shutdown due to loss of AC Power to the site."
109 
110 #define MSGEPOWPCI100 "CEC Rack shutdown due to: 1) Loss of AC power " \
111  "to the CEC Rack,\n" \
112  "2) Open or disconnected SPCN cable between racks\n" \
113  "3) AC module, Bulk power, regulator or SPCN card failure."
114 
115 #define MSGEPOWPCI011 "I/O Rack shutdown due to: 1) Loss of AC power " \
116  "to the I/O Rack,\n" \
117  "2) Open or disconnected SPCN cable between racks,\n" \
118  "3) Power supply failure."
119 
120 #define MSGEPOWPCI001 "Power fault due to internal power supply failure."
121 #define MSGEPOWPCI010 "Power fault due to internal power supply failure."
122 
123 #define MSGEPOWB16b1B17b3 "Power fault due to manual activation of " \
124  "power-off op-panel request."
125 
126 #define MSGEPOWB16b23 "System shutdown due to over temperature condition " \
127  "and fan failure. Use the physical FRU location(s) as the probable " \
128  "cause(s)."
129 
130 #define MSGEPOW1502B16b4 "Non-critical power problem, loss of redundant " \
131  "power supply. Use the physical FRU location(s) as the probable cause(s)."
132 
133 #define MSGEPOW1501B16b4 "Non-critical cooling problem, loss of redundant " \
134  "fan. Use the physical FRU location(s) as the probable cause(s)."
135 
136 #define MSGCRIT_FAN "Sensor indicates a fan has failed."
137 #define MSGCRIT_VOLT "Sensor indicates a voltage is outside the normal range."
138 #define MSGCRIT_THERM "Sensor indicates an abnormally high internal temperature."
139 #define MSGCRIT_POWER "Sensor indicates a power supply has failed."
140 #define MSGCRIT_UNK "Sensor indicates a FRU has failed."
141 #define MSGWARN_FAN "Sensor indicates a fan is turning too slowly."
142 #define MSGRED_FAN "Sensor detected a redundant fan failure."
143 #define MSGRED_POWER "Sensor detected a redundant power supply failure."
144 #define MSGRED_UNK "Sensor detected a redundant FRU failure."
145 
146 #define F_EPOW_ONE "%1$s %2$d"
147 #define F_VOLT_SEN_2 "Volt Sensor"
148 #define F_THERM_SEN "Temp sensor"
149 #define F_POW_SEN "PS sensor"
150 
151 #define MSGREFCODE_CUST "" \
152 "The CEC or SPCN reported an error. Report the SRN and the following reference and physical location codes to your service provider."
153 
154 #define DEFER_MSGREFCODE_CUST ""\
155 "The CEC or SPCN reported a non-critical error. Report the SRN and the following reference and physical location codes to your service provider."
156 
157 #define MSGMENUG150 "651150 ANALYZING SYSTEM ERROR LOG\n" \
158  "A loss of power was detected by one or more\n" \
159  "devices with the following physical location codes:\n\n" \
160  "%s\n\n" \
161  "Check for the following:\n" \
162  " 1. Loose or disconnected power source connections.\n" \
163  " 2. Loss of site power.\n" \
164  " 3. For multiple enclosure systems, loose or\n" \
165  " disconnected power and signal connections\n" \
166  " between enclosures.\n\n" \
167  "If the cause cannot be determined from the list above,\n" \
168  "then replace the FRUs identified by the physical\n" \
169  "locations given above. Refer to the System Service Guide."
170 
171 #define MSGMENUG151 "651151 ANALYZING SYSTEM ERROR LOG\n "\
172  "A loss of power was detected.\n\n" \
173  "Check for the following:\n" \
174  " 1. Loose or disconnected power source connections.\n" \
175  " 2. Loss of site power.\n" \
176  " 3. For multiple enclosure systems, loose or\n" \
177  " disconnected power and/or signal connections\n" \
178  " between enclosures."
179 
180 #define MSGMENUG152 "651152 ANALYZING SYSTEM ERROR LOG\n" \
181  "Environmental sensor analysis is reporting an unknown\n" \
182  "status, with the following physical location codes.\n\n%s\n\n" \
183  "Run the Display System Environmental Sensors Service Aid."
184 
185 #define MSGMENUG153 "651153 ANALYZING SYSTEM ERROR LOG\n" \
186  "Environmental sensor analysis is reporting an unknown\n" \
187  "status. Run the Display System Environmental Sensors Service Aid."
188 
189 #define MSGMENUG156 "651156 ANALYZING SYSTEM ERROR LOG\n" \
190  "A non-critical environmental and power warning was logged.\n" \
191  "The following physical location codes were reported:\n\n%s"
192 
193 #define MSGMENUG157 "651157 ANALYZING SYSTEM ERROR LOG\n" \
194  "A non-critical environmental and power warning was logged."
195 
196 #define MSGMENUG158 "651158 ANALYZING SYSTEM ERROR LOG\n "\
197  "A critical environmental and power warning was logged.\n" \
198  "The following physical location codes were reported:\n" \
199  "\n%s\n\n%s\n\nThe system will shutdown in 10 minutes."
200 
201 #define MSGMENUG159 "651159 ANALYZING SYSTEM ERROR LOG\n" \
202  "A critical environmental and power warning was logged.\n" \
203  "\n%s\n\nThe system will shutdown in 10 minutes."
204 
205 #define MSGMENUG160 "651160 ANALYZING SYSTEM ERROR LOG\n" \
206  "A system shutdown occurred due to a critical \n" \
207  "environmental and power warning.\n" \
208  "The following physical location codes were reported:\n\n%s"
209 
210 #define MSGMENUG161 "651161 ANALYZING SYSTEM ERROR LOG\n" \
211  "A system shutdown occurred due to a critical \n" \
212  "environmental and power warning."
213 
214 #define MSGEPOWB17b0C12 "Power fault due to unspecified cause."
215 #define MSGEPOWB17b0C37 "System shutdown due to power fault with unspecified cause."
216 #define MSGEPOWB16b2C12 "Fan failure. Use the physical FRU location(s) as the probable cause(s)."
217 #define MSGEPOWB16b2C37 "System shutdown due to fan failure. Use the physical FRU location(s) as the probable cause(s)."
218 #define MSGEPOWB17b2RED "Power fault due to internal redundant power supply failure."
219 
220 #define MSG_OP_PANEL_FAIL "Display character test failed."
221 #define F_OP_PANEL "character display logic"
222 
223 #define MSGMENUG162 "651162 ANALYZING SYSTEM ERROR LOG\n" \
224  "An error was logged on %s" \
225  "that indicates the Power-off button was pressed \n" \
226  "without performing a proper shutdown.\n" \
227  "To remove this error from the error log, execute\n" \
228  "the following command from the command line.\n\n" \
229  " errclear -l %d 0"
230 
231 #define DEFER_MSG_UNSUPPORTED_MEM ""\
232  "A non-critical error has been detected: "\
233  "Uncorrectable memory or unsupported memory."
234 
235 #define DEFER_MSGCPUB12b0 "A non-critical error has been detected: "\
236  "CPU internal error."
237 
238 #define DEFER_MSGMEMB12b0 "A non-critical error has been detected: "\
239  "Uncorrectable Memory Error."
240 
241 #define DEFER_MSGMEMB12b1 "A non-critical error has been detected: "\
242  "ECC correctable error."
243 
244 #define DEFER_MSGMEMB12b2 "A non-critical error has been detected: "\
245  "Correctable error threshold exceeded."
246 
247 #define DEFER_MSGIOB13b4 "A non-critical error has been detected: "\
248  "I/O Expansion Bus Parity Error."
249 
250 #define DEFER_MSGIOB13b5 "A non-critical error has been detected: "\
251  "I/O Expansion Bus Time-out Error."
252 
253 #define DEFER_MSGIOB13b6 "A non-critical error has been detected: "\
254  "I/O Expansion Bus Connection Failure."
255 
256 #define DEFER_MSGIOB13b7 "A non-critical error has been detected: "\
257  "I/O Expansion Unit not in an operating state."
258 
259 #define DEFER_MSGIOB12b5 "A non-critical error has been detected: "\
260  "Intermediate or System Bus Address Parity Error."
261 
262 #define DEFER_MSGIOB12b6 "A non-critical error has been detected: "\
263  "Intermediate or System Bus Data Parity Error."
264 
265 #define DEFER_MSGIOB12b7 "A non-critical error has been detected: "\
266  "Intermediate or System Bus Time-out Error."
267 
268 #define MSGPOSTALL "Refer to the Error Code to FRU Index in the system service guide."
269 
270 #define MSGCPUB12b1 "CPU internal cache or cache controller error"
271 
272 #define DEFER_MSGCPUB12b1 "A non-critical error has been detected: "\
273  "CPU internal cache or cache controller error."
274 
275 #define MSGCPUB12b2 "External cache parity or multi-bit ECC error"
276 
277 #define DEFER_MSGCPUB12b2 "A non-critical error has been detected: "\
278  "External cache parity or multi-bit ECC error."
279 
280 #define MSGCPUB12b3 "External cache ECC single-bit error"
281 
282 #define DEFER_MSGCPUB12b3 "A non-critical error has been detected: "\
283  "External cache ECC single-bit error."
284 
285 #define MSGIOB12b3 "I/O bridge/device internal error"
286 
287 #define DEFER_MSGIOB12b3 "A non-critical error has been detected: "\
288  "I/O bridge/device internal error"
289 
290 #define MSG_PLATFORM_ERROR "Platform specific error. Refer to the System " \
291  "Service Guide for this system unit."
292 
293 #define DEFER_MSGALLZERO "A non-critical error has been detected. The error " \
294  "log indicates the following physical FRU location(s) as the probable " \
295  "cause(s)."
296 
297 #define MSGCPUB12b4 "System bus time-out error"
298 
299 #define DEFER_MSGCPUB12b4 "A non-critical error has been detected: " \
300  "System bus time-out error."
301 
302 #define DEFER_MSGCPUB12b5 "A non-critical error has been detected: " \
303  "Time-out error waiting for I/O."
304 
305 #define MSGCPUB12b6 "System bus parity error"
306 
307 #define DEFER_MSGCPUB12b6 "A non-critical error has been detected: "\
308  "System bus parity error."
309 
310 #define MSGCPUB12b7 "System bus protocol/transfer error"
311 
312 #define DEFER_MSGCPUB12b7 "A non-critical error has been detected: "\
313  "System bus protocol/transfer error."
314 
315 #define MSGMEMB12b3 "Memory Controller subsystem internal error"
316 
317 #define DEFER_MSGMEMB12b3 "A non-critical error has been detected: "\
318  "Memory Controller subsystem internal error."
319 
320 #define MSGMEMB12b4 "Memory Address Error (Invalid address or access attempt)"
321 
322 #define DEFER_MSGMEMB12b4 "A non-critical error has been detected: " \
323  "Memory Address (Bad address going to memory)."
324 
325 #define DEFER_MSGMEMB12b5 "A non-critical error has been detected: "\
326  "Memory Data error (Bad data going to memory)."
327 
328 #define DEFER_MSGMEMB12b6 "A non-critical error has been detected: "\
329  "Memory bus/switch internal error."
330 
331 #define DEFER_MSGMEMB12b7 "A non-critical error has been detected: "\
332  "Memory time-out error."
333 
334 #define MSGMEMB13b0 "System bus parity error"
335 
336 #define DEFER_MSGMEMB13b0 "A non-critical error has been detected: "\
337  "System bus parity error."
338 
339 #define MSGMEMB13b1 "System bus time-out error"
340 
341 #define DEFER_MSGMEMB13b1 "A non-critical error has been detected: " \
342  "System bus time-out error."
343 
344 #define MSGMEMB13b2 "System bus protocol/transfer error"
345 
346 #define DEFER_MSGMEMB13b2 "A non-critical error has been detected: " \
347  "System bus protocol/transfer error."
348 
349 #define DEFER_MSGMEMB13b3 "A non-critical error has been detected: " \
350  "I/O Host Bridge time-out error."
351 
352 #define DEFER_MSGMEMB13b4 "A non-critical error has been detected: "\
353  "I/O Host Bridge address/data parity error."
354 
355 #define MSGMEMB13b6 "System support function error."
356 
357 #define DEFER_MSGMEMB13b6 "A non-critical error has been detected: "\
358  "System support function error."
359 
360 #define MSGMEMB13b7 "System bus internal hardware/switch error."
361 
362 #define DEFER_MSGMEMB13b7 "A non-critical error has been detected: "\
363  "System bus internal hardware/switch error."
364 
365 #define DEFER_MSGIOB12b0 "A non-critical error has been detected: "\
366  "I/O Bus Address Parity Error"
367 
368 #define DEFER_MSGIOB12b1 "A non-critical error has been detected: "\
369  "I/O Bus Data Parity Error"
370 
371 #define MSGIOB12b2 "I/O bus time-out, access, or other error"
372 
373 #define DEFER_MSGIOB12b2 "A non-critical error has been detected: " \
374  "I/O Bus time-out, access or other error"
375 
376 #define DEFER_MSGIOB12b4 "A non-critical error has been detected: "\
377  "I/O Error on ISA bus"
378 
379 #define MSG_UNKNOWN_V3 "Error log analysis is unable to determine the " \
380  "error. The error log indicates the following physical FRU location(s) " \
381  "as the probable cause(s)."
382 
383 #define MSGCRIT_FAN_SHUT "System shutdown due to a fan failure."
384 
385 #define MSGCRIT_VOLT_SHUT "System shutdown due to voltage outside the " \
386  "normal range."
387 
388 #define MSGCRIT_THERM_SHUT "System shutdown due to an abnormally high " \
389  "internal temperature."
390 
391 #define MSGCRIT_POWER_SHUT "System shutdown due to a power supply failure."
392 
393 #define MSGSPB19b0 "Power Control Network general connection failure."
394 
395 #define DEFER_MSGSPB19b0 "A non-critical error has been detected: "\
396  "Power Control Network general connection failure."
397 
398 #define MSGSPB19b1 "Power Control Network node failure."
399 
400 #define DEFER_MSGSPB19b1 "A non-critical error has been detected: "\
401  "Power Control Network node failure."
402 
403 #define MSGSPB19b4 "Service Processor error accessing Power Control Network."
404 
405 #define DEFER_MSGSPB19b4 "A non-critical error has been detected: "\
406  "Service Processor error accessing Power Control Network."
407 
408 #define MSGRESERVED "Error with reserved description."
409 
410 #define DEFER_MSGRESERVED "A non-critical error has been detected: "\
411  "Error with reserved description."
412 
413 #define MSGCRIT_UNK_SHUT "System shutdown due to FRU that has failed."
414 
415 #define MSGIOB12b5B13b3 "System bus address parity error"
416 
417 #define DEFER_MSGIOB12b5B13b3 "A non-critical error has been detected: " \
418  "System bus address parity error"
419 
420 #define MSGIOB12b6B13b3 "System bus data parity error"
421 
422 #define DEFER_MSGIOB12b6B13b3 "A non-critical error has been detected: " \
423  "System bus data parity error"
424 
425 #define MSGIOB12b7B13b3 "System bus time-out error"
426 
427 #define DEFER_MSGIOB12b7B13b3 "A non-critical error has been detected: " \
428  "System bus time-out error"
429 
430 #define MSGIOB13b3 "Error on system bus"
431 
432 #define DEFER_MSGIOB13b3 "A non-critical error has been detected: "\
433  "Error on system bus"
434 
435 #define MSGEPOWALLZERO "An environmental and power warning has been detected. "\
436  "The error log indicates the following physical FRU location(s) as the " \
437  "probable cause(s)."
438 
439 #define MSGEPOWB16b2 "Fan failure"
440 
441 #define MSGEPOWB17b2C12 "Internal power supply failure"
442 
443 #define MSGEPOWB17b2C37 "System shutdown due to internal power supply failure"
444 
445 #define MSGEPOWB16b3 "Over temperature condition"
446 
447 #define MSGEPOWB16b2b3 "Over temperature and fan failure"
448 
449 #define MSGSPALLZERO "An error has been detected by the Service Processor. " \
450  "The error log indicates the following physical FRU location(s) as the " \
451  "probable cause(s)."
452 
453 #define DEFER_MSGSPB16b0 "A non-critical error has been detected: " \
454  "Time-out on communication response from Service Processor"
455 
456 #define DEFER_MSGSPB16b1 "A non-critical error has been detected: " \
457  "I/O general bus error"
458 
459 #define DEFER_MSGSPB16b2 "A non-critical error has been detected: " \
460  "Secondary I/O general bus error"
461 
462 #define DEFER_MSGSPB16b3 "A non-critical error has been detected: " \
463  "internal Service Processor memory error"
464 
465 #define DEFER_MSGSPB16b4 "A non-critical error has been detected: " \
466  "Service Processor error accessing special registers"
467 
468 #define DEFER_MSGSPB16b5 "A non-critical error has been detected: " \
469  "Service Processor reports unknown communication error"
470 
471 #define DEFER_MSGSPB16b7 "A non-critical error has been detected: " \
472  "Other internal Service Processor hardware error"
473 
474 #define DEFER_MSGSPB17b0 "A non-critical error has been detected: " \
475  "Service Processor error accessing Vital Product Data EEPROM"
476 
477 #define DEFER_MSGSPB17b1 "A non-critical error has been detected: " \
478  "Service Processor error accessing Operator Panel"
479 
480 #define DEFER_MSGSPB17b2 "A non-critical error has been detected: " \
481  "Service Processor error accessing Power Controller"
482 
483 #define DEFER_MSGSPB17b3 "A non-critical error has been detected: " \
484  "Service Processor error accessing Fan Sensor"
485 
486 #define DEFER_MSGSPB17b4 "A non-critical error has been detected: " \
487  "Service Processor error accessing Thermal Sensor"
488 
489 #define DEFER_MSGSPB17b5 "A non-critical error has been detected: " \
490  "Service Processor error accessing Voltage Sensor"
491 
492 #define DEFER_MSGSPB18b0 "A non-critical error has been detected: " \
493  "Service Processor error accessing serial port"
494 
495 #define MSGSPB18b1 "Service Processor detected NVRAM error"
496 
497 #define DEFER_MSGSPB18b1 "A non-critical error has been detected: " \
498  "Service Processor detected NVRAM error"
499 
500 #define DEFER_MSGSPB18b2 "A non-critical error has been detected: " \
501  "Service Processor error accessing Real-Time Clock/Time-of-day clock"
502 
503 #define DEFER_MSGSPB18b4 "A non-critical error has been detected: " \
504  "Service Processor detects loss of voltage from the battery"
505 
506 #define MSGSPB18b7 "Service Processor detected a surveillance time-out"
507 
508 #define DEFER_MSGSPB18b7 "A non-critical error has been detected: " \
509  "Service Processor detected a surveillance time-out"
510 
511 #define MSGMENUG171 "651171 ANALYZING SYSTEM ERROR LOG\n" \
512  "A problem was logged that could be either hardware, software\n" \
513  "or firmware. If new software or firmware has been recently\n" \
514  "installed, check if there are any known problems. To further\n" \
515  "analyze the problem, enter the following command from the\n" \
516  "command line.\n\n" \
517  " diag -ed sysplanar0"
518 
519 #define PREDICT_UNRECOV "Recoverable errors on resource indicate trend " \
520  "toward unrecoverable error. However the resource could not be " \
521  "deconfigured and is still in use."
522 
523 #define FAIL_BY_PLATFORM "Resource was marked failed by the platform. "\
524  "System is operating in degraded mode."
525 
526 #define MSGMEMB12b4B13b3 "I/O Host Bridge Time-out caused by software"
527 
528 #define MSGMENUG174 "651174 ANALYZING SYSTEM ERROR LOG\n" \
529  "Error log analysis indicates an I/O Host Bridge time-out\n" \
530  "that was caused by software. This error is caused by an\n" \
531  "attempt to access an invalid I/O device address. Contact\n" \
532  "the software support structure for assistance if needed.\n"
533 
534 #define MSGMENUG175 "651175 ANALYZING SYSTEM ERROR LOG\n" \
535  "Error log analysis indicates a power fault that was\n" \
536  "caused by either using the Power-off button without \n" \
537  "performing a proper shutdown, or a loss of power to \nthe system.\n"
538 
539 #define MSGSPB16b6 "Internal Service Processor firmware error or incorrect " \
540  "version"
541 
542 #define DEFER_MSGSPB16b6 "A non-critical error has been detected: "\
543  "Internal Service Processor firmware error or incorrect version"
544 
545 #define MSGSPB18b3 "Service Processor error accessing Scan controller/hardware"
546 
547 #define DEFER_MSGSPB18b3 "A non-critical error has been detected: "\
548  "Service Processor error accessing Scan controller/hardware"
549 
550 #define MSGSPB18b6 "Loss of heart beat from Service Processor"
551 
552 #define DEFER_MSGSPB18b6 "A non-critical error has been detected: " \
553  "Loss of heart beat from Service Processor"
554 
555 #define MSGSPB19b5 "Non-supported hardware"
556 
557 #define DEFER_MSGSPB19b5 "A non-critical error has been detected: "\
558  "Non-supported hardware"
559 
560 #define MSGSPB19b6 "Error detected while handling an attention/interrupt " \
561  "from the system hardware"
562 
563 #define DEFER_MSGSPB19b6 "A non-critical error has been detected: " \
564  "Error detected while handling an attention/interrupt from the " \
565  "system hardware"
566 
567 #define MSGSPB28b1 "Wire Test Error"
568 
569 #define DEFER_MSGSPB28b1 "A non-critical error has been detected: "\
570  "Wire Test Error"
571 
572 #define MSGSPB28b2 "Mainstore or Cache IPL Diagnositc Error"
573 
574 #define DEFER_MSGSPB28b2 "A non-critical error has been detected: " \
575  "Mainstore or Cache IPL Diagnositc Error"
576 
577 #define MSGSPB28b3 "Other IPL Diagnostic Error"
578 
579 #define DEFER_MSGSPB28b3 "A non-critical error has been detected: "\
580  "Other IPL Diagnostic Error"
581 
582 #define MSGSPB28b4 "Clock or PLL Error"
583 
584 #define DEFER_MSGSPB28b4 "A non-critical error has been detected: "\
585  "Clock or PLL Error"
586 
587 #define MSGSPB28b5 "Hardware Scan or Initialization Error"
588 
589 #define DEFER_MSGSPB28b5 "A non-critical error has been detected: "\
590  "Hardware Scan or Initialization Error"
591 
592 #define MSGSPB28b6 "Chip ID Verification Error"
593 
594 #define DEFER_MSGSPB28b6 "A non-critical error has been detected: " \
595  "Chip ID Verification Error"
596 
597 #define MSGSPB28b7 "FRU Presence/Detect Error (Mis-Plugged)"
598 
599 #define DEFER_MSGSPB28b7 "A non-critical error has been detected: " \
600  "FRU Presence/Detect Error (Mis-Plugged)"
601 
602 #define MSGEPOWB16b1B17b4 "Power fault specifically due to internal " \
603  "battery failure"
604 
605 #define MSGMENUG202 "651202 ANALYZING SYSTEM ERROR LOG\n" \
606  "An environmental problem has been corrected and is \n" \
607  "no longer a problem. The problem that was corrected \n" \
608  "can be viewed by using the command:\n" \
609  "\t errpt -a -l %d"
610 
611 #define MSGMENUG203 "651203 ANALYZING SYSTEM ERROR LOG\n" \
612  "An environmental problem has been corrected and is no longer a problem."
613 
614 #define MSGMENUG204 "651204 ANALYZING SYSTEM ERROR LOG\n" \
615  "A loss of redundancy on input power was detected.\n\n" \
616  "Check for the following:\n" \
617  " 1. Loose or disconnected power source connections.\n" \
618  " 2. Loss of the power source.\n" \
619  " 3. For multiple enclosure systems, loose or\n" \
620  " disconnected power and/or signal connections\n" \
621  " between enclosures."
622 
623 #define MSGSPB28b0 "Array or Logic Built in Self Test Error"
624 
625 #define DEFER_MSGSPB28b0 "A non-critical error has been detected: " \
626  "Array or Logic Built in Self Test Error"
627 
628 #define PREDICT_REPAIR_PENDING "Recoverable errors on a resource indicate " \
629  "a potential for an unrecoverable error. The resource cannot be " \
630  "deconfigured and is still in use. The problem may be corrected by "\
631  "array bit steering. Use map 0235."
632 
633 #define MSGMENUG205 "651205 ANALYZING SYSTEM ERROR LOG\n" \
634  "The system lost input power.\n\n" \
635  "If the system has battery backup and input power is\n" \
636  "not restored, then the system will lose all power in\n" \
637  "a few minutes. Take the necessary precautions with\n" \
638  "running applications for a system shut down due to\n" \
639  "loss of power.\n\n" \
640  "If the system does not have battery backup, then this\n" \
641  "message is displayed after power has already been\n" \
642  "restored and your system rebooted successfully.\n\n" \
643  "Check the following for the cause of lost input power:\n" \
644  " 1. Loose or disconnected power source connections.\n" \
645  " 2. Loss of site power.\n" \
646  " 3. For multiple enclosure systems, loose or\n" \
647  " disconnected power and/or signal connections\n "\
648  " between enclosures."
649 
650 #define MSG_BYPASS "The following resource is unavailable due to an error. "\
651  "System is operating in degraded mode."
652 
653 #define MSGMENUG_REFC "\n\nSupporting data:\nRef. Code:\t%X"
654 
655 #define MSGMENUG_LOC "\nLocation Codes:\t%s"
656 
657 #define MSGMENUG206 "651206 ANALYZING SYSTEM ERROR LOG\n" \
658  "The system shutdown because the battery backup\n" \
659  "lost power. The system was running on battery\n" \
660  "backup because of loss of input power."
661 
662 #define MSGMENUGPEL_ERROR "651300 ANALYZING SYSTEM ERROR LOG\n" \
663  "\nThe platform reports the following error:\n\n"
664 
665 #define MSGMENUG_SRC "\n\nSupporting data:\n\nSRC: %s\n"
666 
667 #define MSGMENUG_PRIORITY "Priority: %c %s\n"
668 
669 #define MSGMENUG_FRU "FRU: %s"
670 #define MSGMENUG_EXT_FRU "External FRU: %s"
671 #define MSGMENUG_CODEFRU "Code FRU Procedure: %s"
672 #define MSGMENUG_EXT_CODEFRU "External Code FRU Procedure: %s"
673 #define MSGMENUG_TOOL_FRU "Tool FRU: %s"
674 #define MSGMENUG_SYM_FRU "Symbolic FRU Id: %s"
675 #define MSGMENUG_CFG "Configuration Procedure Id: %s"
676 #define MSGMENUG_MAINT "Maintenance Procedure Id: %s"
677 #define MSGMENUG_RESERVED "Reserved FRU Type: %s"
678 
679 #define MSGMENUG_SERIAL " Serial Number: %s"
680 #define MSGMENUG_CCIN " CCIN: %s"
681 
682 #define MSGMENUG_LOCATION "\nLocation: %s\n"
683 
684 #define MSGMENUGPEL_EVENT "651301 ANALYZING PLATFORM EVENT\n\n"
685 
686 #define V6_INVALID_SUBID "Invalid subsystem ID, cannot determine message."
687 
688 #define V6_RESERVED_SUBID "Reserved subsystem ID, cannot determine message."
689 
690 #define V6_ER_10_00 "Processor subsystem including internal cache " \
691  "Informational (non-error) Event. Refer to the system service " \
692  "documentation for more information."
693 
694 #define V6_ER_10_10 "Processor subsystem including internal cache " \
695  "Recovered Error, general. Refer to the system service documentation " \
696  "for more information."
697 
698 #define V6_ER_10_20 "Processor subsystem including internal cache " \
699  "Predictive Error, general. Refer to the system service documentation " \
700  "for more information."
701 
702 #define V6_ER_10_21 "Processor subsystem including internal cache " \
703  "Predictive Error, degraded performance. Refer to the system service " \
704  "documentation for more information."
705 
706 #define V6_ER_10_22 "Processor subsystem including internal cache " \
707  "Predictive Error, fault may be corrected after platform re-IPL. "\
708  "Refer to the system service documentation for more information."
709 
710 #define V6_ER_10_23 "Processor subsystem including internal cache " \
711  "Predictive Error, fault may be corrected after IPL, degraded " \
712  "performance. Refer to the system service documentation for more " \
713  "information."
714 
715 #define V6_ER_10_24 "Processor subsystem including internal cache " \
716  "Predictive Error, loss of redundancy. Refer to the system service " \
717  "documentation for more information."
718 
719 #define V6_ER_10_40 "Processor subsystem including internal cache " \
720  "Unrecovered Error, general. Refer to the system service documentation " \
721  "for more information."
722 
723 #define V6_ER_10_41 "Processor subsystem including internal cache " \
724  "Unrecovered Error, bypassed with degraded performance. " \
725  "Refer to the system service documentation for more information."
726 
727 #define V6_ER_10_44 "Processor subsystem including internal cache " \
728  "Unrecovered Error, bypassed with loss of redundancy. "\
729  "Refer to the system service documentation for more information."
730 
731 #define V6_ER_10_45 "Processor subsystem including internal cache " \
732  "Unrecovered Error, bypassed with loss of redundancy and performance. "\
733  "Refer to the system service documentation for more information."
734 
735 #define V6_ER_10_48 "Processor subsystem including internal cache " \
736  "Unrecovered Error, bypassed with loss of function. Refer to the " \
737  "system service documentation for more information."
738 
739 #define V6_ER_10_60 "Processor subsystem including internal cache " \
740  "Error on diagnostic test, general. Refer to the system service " \
741  "documentation for more information."
742 
743 #define V6_ER_10_61 "Processor subsystem including internal cache " \
744  "Error on diagnostic test, resource may produce incorrect result. "\
745  "Refer to the system service documentation for more information."
746 
747 #define V6_ER_20_00 "Memory subsystem including external cache " \
748  "Informational (non-error) Event. "\
749  "Refer to the system service documentation for more information."
750 
751 #define V6_ER_20_10 "Memory subsystem including external cache " \
752  "Recovered Error, general. "\
753  "Refer to the system service documentation for more information."
754 
755 #define V6_ER_20_20 "Memory subsystem including external cache " \
756  "Predictive Error, general. " \
757  "Refer to the system service documentation for more information."
758 
759 #define V6_ER_20_21 "Memory subsystem including external cache " \
760  "Predictive Error, degraded performance. "\
761  "Refer to the system service documentation for more information."
762 
763 #define V6_ER_20_22 "Memory subsystem including external cache " \
764  "Predictive Error, fault may be corrected after platform re-IPL. "\
765  "Refer to the system service documentation for more information."
766 
767 #define V6_ER_20_23 "Memory subsystem including external cache " \
768  "Predictive Error, fault may be corrected after IPL, degraded " \
769  "performance. Refer to the system service documentation for more " \
770  "information."
771 
772 #define V6_ER_20_24 "Memory subsystem including external cache " \
773  "Predictive Error, loss of redundancy. "\
774  "Refer to the system service documentation for more information."
775 
776 #define V6_ER_20_40 "Memory subsystem including external cache " \
777  "Unrecovered Error, general. "\
778  "Refer to the system service documentation for more information."
779 
780 #define V6_ER_20_41 "Memory subsystem including external cache " \
781  "Unrecovered Error, bypassed with degraded performance. " \
782  "Refer to the system service documentation for more information."
783 
784 #define V6_ER_20_44 "Memory subsystem including external cache " \
785  "Unrecovered Error, bypassed with loss of redundancy. " \
786  "Refer to the system service documentation for more information."
787 
788 #define V6_ER_20_45 "Memory subsystem including external cache " \
789  "Unrecovered Error, bypassed with loss of redundancy and performance. " \
790  "Refer to the system service documentation for more information."
791 
792 #define V6_ER_20_48 "Memory subsystem including external cache " \
793  "Unrecovered Error, bypassed with loss of function. " \
794  "Refer to the system service documentation for more information."
795 
796 #define V6_ER_20_60 "Memory subsystem including external cache " \
797  "Error on diagnostic test, general. " \
798  "Refer to the system service documentation for more information."
799 
800 #define V6_ER_20_61 "Memory subsystem including external cache Error on " \
801  "diagnostic test, resource may produce incorrect result. "\
802  "Refer to the system service documentation for more information."
803 
804 #define V6_ER_30_00 "I/O subsystem (hub, bridge, bus) Informational " \
805  "(non-error) Event. " \
806  "Refer to the system service documentation for more information."
807 
808 #define V6_ER_30_10 "I/O subsystem (hub, bridge, bus) Recovered " \
809  "Error, general. " \
810  "Refer to the system service documentation for more information."
811 
812 #define V6_ER_30_20 "I/O subsystem (hub, bridge, bus) Predictive " \
813  "Error, general. " \
814  "Refer to the system service documentation for more information."
815 
816 #define V6_ER_30_21 "I/O subsystem (hub, bridge, bus) Predictive Error, " \
817  "degraded performance. " \
818  "Refer to the system service documentation for more information."
819 
820 #define V6_ER_30_22 "I/O subsystem (hub, bridge, bus) Predictive Error, " \
821  "fault may be corrected after platform re-IPL. " \
822  "Refer to the system service documentation for more information."
823 
824 #define V6_ER_30_23 "I/O subsystem (hub, bridge, bus) Predictive Error, " \
825  "fault may be corrected after IPL, degraded performance. "\
826  "Refer to the system service documentation for more information."
827 
828 #define V6_ER_30_24 "I/O subsystem (hub, bridge, bus) Predictive Error, " \
829  "loss of redundancy. " \
830  "Refer to the system service documentation for more information."
831 
832 #define V6_ER_30_40 "I/O subsystem (hub, bridge, bus) Unrecovered Error, " \
833  "general. " \
834  "Refer to the system service documentation for more information."
835 
836 #define V6_ER_30_41 "I/O subsystem (hub, bridge, bus) Unrecovered Error, " \
837  "bypassed with degraded performance. " \
838  "Refer to the system service documentation for more information."
839 
840 #define V6_ER_30_44 "I/O subsystem (hub, bridge, bus) Unrecovered Error, " \
841  "bypassed with loss of redundancy. "\
842  "Refer to the system service documentation for more information."
843 
844 #define V6_ER_30_45 "I/O subsystem (hub, bridge, bus) Unrecovered Error, " \
845  "bypassed with loss of redundancy and performance. " \
846  "Refer to the system service documentation for more information."
847 
848 #define V6_ER_30_48 "I/O subsystem (hub, bridge, bus) Unrecovered Error, " \
849  "bypassed with loss of function. " \
850  "Refer to the system service documentation for more information."
851 
852 #define V6_ER_30_60 "I/O subsystem (hub, bridge, bus) Error on " \
853  "diagnostic test, general. " \
854  "Refer to the system service documentation for more information."
855 
856 #define V6_ER_30_61 "I/O subsystem (hub, bridge, bus) Error on " \
857  "diagnostic test, resource may produce incorrect result. " \
858  "Refer to the system service documentation for more information."
859 
860 #define V6_ER_40_00 "I/O adapter, device and peripheral Informational " \
861  "(non-error) Event. " \
862  "Refer to the system service documentation for more information."
863 
864 #define V6_ER_40_10 "I/O adapter, device and peripheral Recovered Error, " \
865  "general. "\
866  "Refer to the system service documentation for more information."
867 
868 #define V6_ER_40_20 "I/O adapter, device and peripheral Predictive Error, " \
869  "general. "\
870  "Refer to the system service documentation for more information."
871 
872 #define V6_ER_40_21 "I/O adapter, device and peripheral Predictive Error, " \
873  "degraded performance. " \
874  "Refer to the system service documentation for more information."
875 
876 #define V6_ER_40_22 "I/O adapter, device and peripheral Predictive Error, " \
877  "fault may be corrected after platform re-IPL. "\
878  "Refer to the system service documentation for more information."
879 
880 #define V6_ER_40_23 "I/O adapter, device and peripheral Predictive Error, " \
881  "fault may be corrected after IPL, degraded performance. " \
882  "Refer to the system service documentation for more information."
883 
884 #define V6_ER_40_24 "I/O adapter, device and peripheral Predictive Error, " \
885  "loss of redundancy. "\
886  "Refer to the system service documentation for more information."
887 
888 #define V6_ER_40_40 "I/O adapter, device and peripheral Unrecovered Error, " \
889  "general. "\
890  "Refer to the system service documentation for more information."
891 
892 #define V6_ER_40_41 "I/O adapter, device and peripheral Unrecovered Error, " \
893  "bypassed with degraded performance. "\
894  "Refer to the system service documentation for more information."
895 
896 #define V6_ER_40_44 "I/O adapter, device and peripheral Unrecovered Error, " \
897  "bypassed with loss of redundancy. "\
898  "Refer to the system service documentation for more information."
899 
900 #define V6_ER_40_45 "I/O adapter, device and peripheral Unrecovered Error, " \
901  "bypassed with loss of redundancy and performance. " \
902  "Refer to the system service documentation for more information."
903 
904 #define V6_ER_40_48 "I/O adapter, device and peripheral Unrecovered Error, " \
905  "bypassed with loss of function. " \
906  "Refer to the system service documentation for more information."
907 
908 #define V6_ER_40_60 "I/O adapter, device and peripheral Error on diagnostic " \
909  "test, general. "\
910  "Refer to the system service documentation for more information."
911 
912 #define V6_ER_40_61 "I/O adapter, device and peripheral Error on diagnostic " \
913  "test, resource may produce incorrect result. " \
914  "Refer to the system service documentation for more information."
915 
916 #define V6_ER_50_00 "CEC hardware Informational (non-error) Event. "\
917  "Refer to the system service documentation for more information."
918 
919 #define V6_ER_50_10 "CEC hardware Recovered Error, general. " \
920  "Refer to the system service documentation for more information."
921 
922 #define V6_ER_50_20 "CEC hardware Predictive Error, general. " \
923  "Refer to the system service documentation for more information."
924 
925 #define V6_ER_50_21 "CEC hardware Predictive Error, degraded performance. " \
926  "Refer to the system service documentation for more information."
927 
928 #define V6_ER_50_22 "CEC hardware Predictive Error, fault may be " \
929  "corrected after platform re-IPL. " \
930  "Refer to the system service documentation for more information."
931 
932 #define V6_ER_50_23 "CEC hardware Predictive Error, fault may be " \
933  "corrected after IPL, degraded performance. "\
934  "Refer to the system service documentation for more information."
935 
936 #define V6_ER_50_24 "CEC hardware Predictive Error, loss of redundancy. " \
937  "Refer to the system service documentation for more information."
938 
939 #define V6_ER_50_40 "CEC hardware Unrecovered Error, general. " \
940  "Refer to the system service documentation for more information."
941 
942 #define V6_ER_50_41 "CEC hardware Unrecovered Error, bypassed with " \
943  "degraded performance. " \
944  "Refer to the system service documentation for more information."
945 
946 #define V6_ER_50_44 "CEC hardware Unrecovered Error, bypassed with " \
947  "loss of redundancy. "\
948  "Refer to the system service documentation for more information."
949 
950 #define V6_ER_50_45 "CEC hardware Unrecovered Error, bypassed with " \
951  "loss of redundancy and performance. " \
952  "Refer to the system service documentation for more information."
953 
954 #define V6_ER_50_48 "CEC hardware Unrecovered Error, bypassed with " \
955  "loss of function. " \
956  "Refer to the system service documentation for more information."
957 
958 #define V6_ER_50_60 "CEC hardware Error on diagnostic test, general. " \
959  "Refer to the system service documentation for more information."
960 
961 #define V6_ER_50_61 "CEC hardware Error on diagnostic test, resource " \
962  "may produce incorrect result. " \
963  "Refer to the system service documentation for more information."
964 
965 #define V6_ER_60_00 "Power/Cooling subsystem Informational (non-error) Event."\
966  "Refer to the system service documentation for more information."
967 
968 #define V6_ER_60_10 "Power/Cooling subsystem Recovered Error, general. " \
969  "Refer to the system service documentation for more information."
970 
971 #define V6_ER_60_20 "Power/Cooling subsystem Predictive Error, general. " \
972  "Refer to the system service documentation for more information."
973 
974 #define V6_ER_60_21 "Power/Cooling subsystem Predictive Error, " \
975  "degraded performance. "\
976  "Refer to the system service documentation for more information."
977 
978 #define V6_ER_60_22 "Power/Cooling subsystem Predictive Error, " \
979  "fault may be corrected after platform re-IPL. " \
980  "Refer to the system service documentation for more information."
981 
982 #define V6_ER_60_23 "Power/Cooling subsystem Predictive Error, " \
983  "fault may be corrected after IPL, degraded performance. "\
984  "Refer to the system service documentation for more information."
985 
986 #define V6_ER_60_24 "Power/Cooling subsystem Predictive Error, " \
987  "loss of redundancy. " \
988  "Refer to the system service documentation for more information."
989 
990 #define V6_ER_60_40 "Power/Cooling subsystem Unrecovered Error, general. "\
991  "Refer to the system service documentation for more information."
992 
993 #define V6_ER_60_41 "Power/Cooling subsystem Unrecovered Error, " \
994  "bypassed with degraded performance. " \
995  "Refer to the system service documentation for more information."
996 
997 #define V6_ER_60_44 "Power/Cooling subsystem Unrecovered Error, " \
998  "bypassed with loss of redundancy. "\
999  "Refer to the system service documentation for more information."
1000 
1001 #define V6_ER_60_45 "Power/Cooling subsystem Unrecovered Error, " \
1002  "bypassed with loss of redundancy and performance. " \
1003  "Refer to the system service documentation for more information."
1004 
1005 #define V6_ER_60_48 "Power/Cooling subsystem Unrecovered Error, " \
1006  "bypassed with loss of function. "\
1007  "Refer to the system service documentation for more information."
1008 
1009 #define V6_ER_60_60 "Power/Cooling subsystem Error on diagnostic test, " \
1010  "general. "\
1011  "Refer to the system service documentation for more information."
1012 
1013 #define V6_ER_60_61 "Power/Cooling subsystem Error on diagnostic test, " \
1014  "resource may produce incorrect result. " \
1015  "Refer to the system service documentation for more information."
1016 
1017 #define V6_ER_70_00 "Other subsystem Informational (non-error) Event. " \
1018  "Refer to the system service documentation for more information."
1019 
1020 #define V6_ER_70_10 "Other subsystem Recovered Error, general. " \
1021  "Refer to the system service documentation for more information."
1022 
1023 #define V6_ER_70_20 "Other subsystem Predictive Error, general. " \
1024  "Refer to the system service documentation for more information."
1025 
1026 #define V6_ER_70_21 "Other subsystem Predictive Error, degraded performance."\
1027  "Refer to the system service documentation for more information."
1028 
1029 #define V6_ER_70_22 "Other subsystem Predictive Error, " \
1030  "fault may be corrected after platform re-IPL. " \
1031  "Refer to the system service documentation for more information."
1032 
1033 #define V6_ER_70_23 "Other subsystem Predictive Error, " \
1034  "fault may be corrected after IPL, degraded performance. "\
1035  "Refer to the system service documentation for more information."
1036 
1037 #define V6_ER_70_24 "Other subsystem Predictive Error, loss of redundancy. "\
1038  "Refer to the system service documentation for more information."
1039 
1040 #define V6_ER_70_40 "Other subsystem Unrecovered Error, general. " \
1041  "Refer to the system service documentation for more information."
1042 
1043 #define V6_ER_70_41 "Other subsystem Unrecovered Error, " \
1044  "bypassed with degraded performance. "\
1045  "Refer to the system service documentation for more information."
1046 
1047 #define V6_ER_70_44 "Other subsystem Unrecovered Error, " \
1048  "bypassed with loss of redundancy. " \
1049  "Refer to the system service documentation for more information."
1050 
1051 #define V6_ER_70_45 "Other subsystem Unrecovered Error, " \
1052  "bypassed with loss of redundancy and performance. "\
1053  "Refer to the system service documentation for more information."
1054 
1055 #define V6_ER_70_48 "Other subsystem Unrecovered Error, " \
1056  "bypassed with loss of function. " \
1057  "Refer to the system service documentation for more information."
1058 
1059 #define V6_ER_70_60 "Other subsystem Error on diagnostic test, general. " \
1060  "Refer to the system service documentation for more information."
1061 
1062 #define V6_ER_70_61 "Other subsystem Error on diagnostic test, " \
1063  "resource may produce incorrect result. " \
1064  "Refer to the system service documentation for more information."
1065 
1066 #define V6_ER_7A_00 "Surveillance Error Informational (non-error) Event. "\
1067  "Refer to the system service documentation for more information."
1068 
1069 #define V6_ER_7A_10 "Surveillance Error Recovered Error, general. "\
1070  "Refer to the system service documentation for more information."
1071 
1072 #define V6_ER_7A_20 "Surveillance Error Predictive Error, general. " \
1073  "Refer to the system service documentation for more information."
1074 
1075 #define V6_ER_7A_21 "Surveillance Error Predictive Error, " \
1076  "degraded performance. " \
1077  "Refer to the system service documentation for more information."
1078 
1079 #define V6_ER_7A_22 "Surveillance Error Predictive Error, " \
1080  "fault may be corrected after platform re-IPL. " \
1081  "Refer to the system service documentation for more information."
1082 
1083 #define V6_ER_7A_23 "Surveillance Error Predictive Error, " \
1084  "fault may be corrected after IPL, degraded performance. " \
1085  "Refer to the system service documentation for more information."
1086 
1087 #define V6_ER_7A_24 "Surveillance Error Predictive Error, " \
1088  "loss of redundancy. " \
1089  "Refer to the system service documentation for more information."
1090 
1091 #define V6_ER_7A_40 "Surveillance Error Unrecovered Error, general. " \
1092  "Refer to the system service documentation for more information."
1093 
1094 #define V6_ER_7A_41 "Surveillance Error Unrecovered Error, " \
1095  "bypassed with degraded performance. " \
1096  "Refer to the system service documentation for more information."
1097 
1098 #define V6_ER_7A_44 "Surveillance Error Unrecovered Error, " \
1099  "bypassed with loss of redundancy. "\
1100  "Refer to the system service documentation for more information."
1101 
1102 #define V6_ER_7A_45 "Surveillance Error Unrecovered Error, " \
1103  "bypassed with loss of redundancy and performance. " \
1104  "Refer to the system service documentation for more information."
1105 
1106 #define V6_ER_7A_48 "Surveillance Error Unrecovered Error, " \
1107  "bypassed with loss of function. " \
1108  "Refer to the system service documentation for more information."
1109 
1110 #define V6_ER_7A_60 "Surveillance Error Error on diagnostic test, general. " \
1111  "Refer to the system service documentation for more information."
1112 
1113 #define V6_ER_7A_61 "Surveillance Error Error on diagnostic test, " \
1114  "resource may produce incorrect result. " \
1115  "Refer to the system service documentation for more information."
1116 
1117 #define V6_ER_80_00 "Platform Firmware Informational (non-error) Event. " \
1118  "Refer to the system service documentation for more information."
1119 
1120 #define V6_ER_80_10 "Platform Firmware Recovered Error, general. " \
1121  "Refer to the system service documentation for more information."
1122 
1123 #define V6_ER_80_20 "Platform Firmware Predictive Error, general. " \
1124  "Refer to the system service documentation for more information."
1125 
1126 #define V6_ER_80_21 "Platform Firmware Predictive Error, " \
1127  "degraded performance. " \
1128  "Refer to the system service documentation for more information."
1129 
1130 #define V6_ER_80_22 "Platform Firmware Predictive Error, " \
1131  "fault may be corrected after platform re-IPL. " \
1132  "Refer to the system service documentation for more information."
1133 
1134 #define V6_ER_80_23 "Platform Firmware Predictive Error, " \
1135  "fault may be corrected after IPL, degraded performance. " \
1136  "Refer to the system service documentation for more information."
1137 
1138 #define V6_ER_80_24 "Platform Firmware Predictive Error, loss of redundancy. "\
1139  "Refer to the system service documentation for more information."
1140 
1141 #define V6_ER_80_40 "Platform Firmware Unrecovered Error, general. " \
1142  "Refer to the system service documentation for more information."
1143 
1144 #define V6_ER_80_41 "Platform Firmware Unrecovered Error, " \
1145  "bypassed with degraded performance. " \
1146  "Refer to the system service documentation for more information."
1147 
1148 #define V6_ER_80_44 "Platform Firmware Unrecovered Error, " \
1149  "bypassed with loss of redundancy. " \
1150  "Refer to the system service documentation for more information."
1151 
1152 #define V6_ER_80_45 "Platform Firmware Unrecovered Error, " \
1153  "bypassed with loss of redundancy and performance. " \
1154  "Refer to the system service documentation for more information."
1155 
1156 #define V6_ER_80_48 "Platform Firmware Unrecovered Error, " \
1157  "bypassed with loss of function. " \
1158  "Refer to the system service documentation for more information."
1159 
1160 #define V6_ER_80_60 "Platform Firmware Error on diagnostic test, general. " \
1161  "Refer to the system service documentation for more information."
1162 
1163 #define V6_ER_80_61 "Platform Firmware Error on diagnostic test, " \
1164  "resource may produce incorrect result. " \
1165  "Refer to the system service documentation for more information."
1166 
1167 #define V6_ER_90_00 "Software Informational (non-error) Event. " \
1168  "Refer to the system service documentation for more information."
1169 
1170 #define V6_ER_90_10 "Software Recovered Error, general. " \
1171  "Refer to the system service documentation for more information."
1172 
1173 #define V6_ER_90_20 "Software Predictive Error, general. " \
1174  "Refer to the system service documentation for more information."
1175 
1176 #define V6_ER_90_21 "Software Predictive Error, degraded performance. " \
1177  "Refer to the system service documentation for more information."
1178 
1179 #define V6_ER_90_22 "Software Predictive Error, " \
1180  "fault may be corrected after platform re-IPL. " \
1181  "Refer to the system service documentation for more information."
1182 
1183 #define V6_ER_90_23 "Software Predictive Error, " \
1184  "fault may be corrected after IPL, degraded performance. " \
1185  "Refer to the system service documentation for more information."
1186 
1187 #define V6_ER_90_24 "Software Predictive Error, loss of redundancy. " \
1188  "Refer to the system service documentation for more information."
1189 
1190 #define V6_ER_90_40 "Software Unrecovered Error, general. " \
1191  "Refer to the system service documentation for more information."
1192 
1193 #define V6_ER_90_41 "Software Unrecovered Error, " \
1194  "bypassed with degraded performance. " \
1195  "Refer to the system service documentation for more information."
1196 
1197 #define V6_ER_90_44 "Software Unrecovered Error, "\
1198  "bypassed with loss of redundancy. " \
1199  "Refer to the system service documentation for more information."
1200 
1201 #define V6_ER_90_45 "Software Unrecovered Error, " \
1202  "bypassed with loss of redundancy and performance. " \
1203  "Refer to the system service documentation for more information."
1204 
1205 #define V6_ER_90_48 "Software Unrecovered Error, " \
1206  "bypassed with loss of function. " \
1207  "Refer to the system service documentation for more information."
1208 
1209 #define V6_ER_90_60 "Software Error on diagnostic test, general. "\
1210  "Refer to the system service documentation for more information."
1211 
1212 #define V6_ER_90_61 "Software Error on diagnostic test, " \
1213  "resource may produce incorrect result. " \
1214  "Refer to the system service documentation for more information."
1215 
1216 #define V6_ER_A0_00 "External environment Informational (non-error) Event. "\
1217  "Refer to the system service documentation for more information."
1218 
1219 #define V6_ER_A0_10 "External environment Recovered Error, general. " \
1220  "Refer to the system service documentation for more information."
1221 
1222 #define V6_ER_A0_20 "External environment Predictive Error, general. " \
1223  "Refer to the system service documentation for more information."
1224 
1225 #define V6_ER_A0_21 "External environment Predictive Error, " \
1226  "degraded performance. "\
1227  "Refer to the system service documentation for more information."
1228 
1229 #define V6_ER_A0_22 "External environment Predictive Error, " \
1230  "fault may be corrected after platform re-IPL. " \
1231  "Refer to the system service documentation for more information."
1232 
1233 #define V6_ER_A0_23 "External environment Predictive Error, " \
1234  "fault may be corrected after IPL, degraded performance. " \
1235  "Refer to the system service documentation for more information."
1236 
1237 #define V6_ER_A0_24 "External environment Predictive Error, " \
1238  "loss of redundancy. " \
1239  "Refer to the system service documentation for more information."
1240 
1241 #define V6_ER_A0_40 "External environment Unrecovered Error, general. " \
1242  "Refer to the system service documentation for more information."
1243 
1244 #define V6_ER_A0_41 "External environment Unrecovered Error, " \
1245  "bypassed with degraded performance. " \
1246  "Refer to the system service documentation for more information."
1247 
1248 #define V6_ER_A0_44 "External environment Unrecovered Error, " \
1249  "bypassed with loss of redundancy. " \
1250  "Refer to the system service documentation for more information."
1251 
1252 #define V6_ER_A0_45 "External environment Unrecovered Error, " \
1253  "bypassed with loss of redundancy and performance. " \
1254  "Refer to the system service documentation for more information."
1255 
1256 #define V6_ER_A0_48 "External environment Unrecovered Error, " \
1257  "bypassed with loss of function. " \
1258  "Refer to the system service documentation for more information."
1259 
1260 #define V6_ER_A0_60 "External environment Error on diagnostic test, general. "\
1261  "Refer to the system service documentation for more information."
1262 
1263 #define V6_ER_A0_61 "External environment Error on diagnostic test, " \
1264  "resource may produce incorrect result. " \
1265  "Refer to the system service documentation for more information."
1266 
1267 #define V6_ER_B0_00 "Reserved Informational (non-error) Event. " \
1268  "Refer to the system service documentation for more information."
1269 
1270 #define V6_ER_B0_10 "Reserved Recovered Error, general. " \
1271  "Refer to the system service documentation for more information."
1272 
1273 #define V6_ER_B0_20 "Reserved Predictive Error, general. " \
1274  "Refer to the system service documentation for more information."
1275 
1276 #define V6_ER_B0_21 "Reserved Predictive Error, degraded performance. " \
1277  "Refer to the system service documentation for more information."
1278 
1279 #define V6_ER_B0_22 "Reserved Predictive Error, " \
1280  "fault may be corrected after platform re-IPL. " \
1281  "Refer to the system service documentation for more information."
1282 
1283 #define V6_ER_B0_23 "Reserved Predictive Error, " \
1284  "fault may be corrected after IPL, degraded performance. " \
1285  "Refer to the system service documentation for more information."
1286 
1287 #define V6_ER_B0_24 "Reserved Predictive Error, loss of redundancy. "\
1288  "Refer to the system service documentation for more information."
1289 
1290 #define V6_ER_B0_40 "Reserved Unrecovered Error, general. " \
1291  "Refer to the system service documentation for more information."
1292 
1293 #define V6_ER_B0_41 "Reserved Unrecovered Error, " \
1294  "bypassed with degraded performance. " \
1295  "Refer to the system service documentation for more information."
1296 
1297 #define V6_ER_B0_44 "Reserved Unrecovered Error, " \
1298  "bypassed with loss of redundancy. " \
1299  "Refer to the system service documentation for more information."
1300 
1301 #define V6_ER_B0_45 "Reserved Unrecovered Error, " \
1302  "bypassed with loss of redundancy and performance. " \
1303  "Refer to the system service documentation for more information."
1304 
1305 #define V6_ER_B0_48 "Reserved Unrecovered Error, " \
1306  "bypassed with loss of function. " \
1307  "Refer to the system service documentation for more information."
1308 
1309 #define V6_ER_B0_60 "Reserved Error on diagnostic test, general. " \
1310  "Refer to the system service documentation for more information."
1311 
1312 #define V6_ER_B0_61 "Reserved Error on diagnostic test, " \
1313  "resource may produce incorrect result. " \
1314  "Refer to the system service documentation for more information."
1315 
1316 #define V6_EV_10_00 "Processor subsystem including internal cache Not " \
1317  "applicable."
1318 
1319 #define V6_EV_10_01 "Processor subsystem including internal cache " \
1320  "Miscellaneous, Information Only."
1321 
1322 #define V6_EV_10_08 "Processor subsystem including internal cache " \
1323  "Dump Notification."
1324 
1325 #define V6_EV_10_10 "Processor subsystem including internal cache " \
1326  "Previously reported error has been corrected by the system."
1327 
1328 #define V6_EV_10_20 "Processor subsystem including internal cache " \
1329  "System resources manually deconfigured by user."
1330 
1331 #define V6_EV_10_21 "Processor subsystem including internal cache " \
1332  "System resources deconfigured by system due to prior error event."
1333 
1334 #define V6_EV_10_22 "Processor subsystem including internal cache " \
1335  "Resource deallocation event notification."
1336 
1337 #define V6_EV_10_30 "Processor subsystem including internal cache " \
1338  "Customer environmental problem has returned to normal."
1339 
1340 #define V6_EV_10_40 "Processor subsystem including internal cache " \
1341  "Concurrent Maintenance Event."
1342 
1343 #define V6_EV_10_60 "Processor subsystem including internal cache " \
1344  "Capacity Upgrade Event."
1345 
1346 #define V6_EV_10_70 "Processor subsystem including internal cache " \
1347  "Resource Sparing Event."
1348 
1349 #define V6_EV_10_80 "Processor subsystem including internal cache " \
1350  "Dynamic Reconfiguration Event."
1351 
1352 #define V6_EV_10_D0 "Processor subsystem including internal cache " \
1353  "Normal system/platform shutdown or powered off."
1354 
1355 #define V6_EV_10_E0 "Processor subsystem including internal cache " \
1356  "Platform powered off by user with normal shutdown."
1357 
1358 #define V6_EV_20_00 "Memory subsystem including external cache " \
1359  "Not applicable."
1360 
1361 #define V6_EV_20_01 "Memory subsystem including external cache " \
1362  "Miscellaneous, Information Only."
1363 
1364 #define V6_EV_20_08 "Memory subsystem including external cache " \
1365  "Dump Notification."
1366 
1367 #define V6_EV_20_10 "Memory subsystem including external cache " \
1368  "Previously reported error has been corrected by the system."
1369 
1370 #define V6_EV_20_20 "Memory subsystem including external cache " \
1371  "System resources manually deconfigured by user."
1372 
1373 #define V6_EV_20_21 "Memory subsystem including external cache " \
1374  "System resources deconfigured by system due to prior error event."
1375 
1376 #define V6_EV_20_22 "Memory subsystem including external cache " \
1377  "Resource deallocation event notification."
1378 
1379 #define V6_EV_20_30 "Memory subsystem including external cache " \
1380  "Customer environmental problem has returned to normal."
1381 
1382 #define V6_EV_20_40 "Memory subsystem including external cache " \
1383  "Concurrent Maintenance Event."
1384 
1385 #define V6_EV_20_60 "Memory subsystem including external cache " \
1386  "Capacity Upgrade Event."
1387 
1388 #define V6_EV_20_70 "Memory subsystem including external cache " \
1389  "Resource Sparing Event."
1390 
1391 #define V6_EV_20_80 "Memory subsystem including external cache " \
1392  "Dynamic Reconfiguration Event."
1393 
1394 #define V6_EV_20_D0 "Memory subsystem including external cache " \
1395  "Normal system/platform shutdown or powered off."
1396 
1397 #define V6_EV_20_E0 "Memory subsystem including external cache " \
1398  "Platform powered off by user with normal shutdown."
1399 
1400 #define V6_EV_30_00 "I/O subsystem (hub, bridge, bus) Not applicable."
1401 
1402 #define V6_EV_30_01 "I/O subsystem (hub, bridge, bus) " \
1403  "Miscellaneous, Information Only."
1404 
1405 #define V6_EV_30_08 "I/O subsystem (hub, bridge, bus) " \
1406  "Dump Notification."
1407 
1408 #define V6_EV_30_10 "I/O subsystem (hub, bridge, bus) " \
1409  "Previously reported error has been corrected by the system."
1410 
1411 #define V6_EV_30_20 "I/O subsystem (hub, bridge, bus) " \
1412  "System resources manually deconfigured by user."
1413 
1414 #define V6_EV_30_21 "I/O subsystem (hub, bridge, bus) " \
1415  "System resources deconfigured by system due to prior error event."
1416 
1417 #define V6_EV_30_22 "I/O subsystem (hub, bridge, bus) " \
1418  "Resource deallocation event notification."
1419 
1420 #define V6_EV_30_30 "I/O subsystem (hub, bridge, bus) " \
1421  "Customer environmental problem has returned to normal."
1422 
1423 #define V6_EV_30_40 "I/O subsystem (hub, bridge, bus) " \
1424  "Concurrent Maintenance Event."
1425 
1426 #define V6_EV_30_60 "I/O subsystem (hub, bridge, bus) Capacity Upgrade Event."
1427 
1428 #define V6_EV_30_70 "I/O subsystem (hub, bridge, bus) Resource Sparing Event."
1429 
1430 #define V6_EV_30_80 "I/O subsystem (hub, bridge, bus) " \
1431  "Dynamic Reconfiguration Event."
1432 
1433 #define V6_EV_30_D0 "I/O subsystem (hub, bridge, bus) " \
1434  "Normal system/platform shutdown or powered off."
1435 
1436 #define V6_EV_30_E0 "I/O subsystem (hub, bridge, bus) " \
1437  "Platform powered off by user with normal shutdown."
1438 
1439 #define V6_EV_40_00 "I/O adapter, device and peripheral Not applicable."
1440 
1441 #define V6_EV_40_01 "I/O adapter, device and peripheral " \
1442  "Miscellaneous, Information Only."
1443 
1444 #define V6_EV_40_08 "I/O adapter, device and peripheral " \
1445  "Dump Notification."
1446 
1447 #define V6_EV_40_10 "I/O adapter, device and peripheral " \
1448  "Previously reported error has been corrected by the system."
1449 
1450 #define V6_EV_40_20 "I/O adapter, device and peripheral " \
1451  "System resources manually deconfigured by user."
1452 
1453 #define V6_EV_40_21 "I/O adapter, device and peripheral " \
1454  "System resources deconfigured by system due to prior error event."
1455 
1456 #define V6_EV_40_22 "I/O adapter, device and peripheral " \
1457  "Resource deallocation event notification."
1458 
1459 #define V6_EV_40_30 "I/O adapter, device and peripheral " \
1460  "Customer environmental problem has returned to normal."
1461 
1462 #define V6_EV_40_40 "I/O adapter, device and peripheral " \
1463  "Concurrent Maintenance Event."
1464 
1465 #define V6_EV_40_60 "I/O adapter, device and peripheral " \
1466  "Capacity Upgrade Event."
1467 
1468 #define V6_EV_40_70 "I/O adapter, device and peripheral " \
1469  "Resource Sparing Event."
1470 
1471 #define V6_EV_40_80 "I/O adapter, device and peripheral " \
1472  "Dynamic Reconfiguration Event."
1473 
1474 #define V6_EV_40_D0 "I/O adapter, device and peripheral " \
1475  "Normal system/platform shutdown or powered off."
1476 
1477 #define V6_EV_40_E0 "I/O adapter, device and peripheral " \
1478  "Platform powered off by user with normal shutdown."
1479 
1480 #define V6_EV_50_00 "CEC hardware Not applicable."
1481 
1482 #define V6_EV_50_01 "CEC hardware Miscellaneous, Information Only."
1483 
1484 #define V6_EV_50_08 "CEC hardware Dump Notification."
1485 
1486 #define V6_EV_50_10 "CEC hardware " \
1487  "Previously reported error has been corrected by the system."
1488 
1489 #define V6_EV_50_20 "CEC hardware " \
1490  "System resources manually deconfigured by user."
1491 
1492 #define V6_EV_50_21 "CEC hardware " \
1493  "System resources deconfigured by system due to prior error event."
1494 
1495 #define V6_EV_50_22 "CEC hardware Resource deallocation event notification."
1496 
1497 #define V6_EV_50_30 "CEC hardware " \
1498  "Customer environmental problem has returned to normal."
1499 
1500 #define V6_EV_50_40 "CEC hardware Concurrent Maintenance Event."
1501 
1502 #define V6_EV_50_60 "CEC hardware Capacity Upgrade Event."
1503 
1504 #define V6_EV_50_70 "CEC hardware Resource Sparing Event."
1505 
1506 #define V6_EV_50_80 "CEC hardware Dynamic Reconfiguration Event."
1507 
1508 #define V6_EV_50_D0 "CEC hardware " \
1509  "Normal system/platform shutdown or powered off."
1510 
1511 #define V6_EV_50_E0 "CEC hardware " \
1512  "Platform powered off by user with normal shutdown."
1513 
1514 #define V6_EV_60_00 "Power/Cooling subsystem Not applicable."
1515 
1516 #define V6_EV_60_01 "Power/Cooling subsystem Miscellaneous, Information Only."
1517 
1518 #define V6_EV_60_08 "Power/Cooling subsystem Dump Notification."
1519 
1520 #define V6_EV_60_10 "Power/Cooling subsystem " \
1521  "Previously reported error has been corrected by the system."
1522 
1523 #define V6_EV_60_20 "Power/Cooling subsystem " \
1524  "System resources manually deconfigured by user."
1525 
1526 #define V6_EV_60_21 "Power/Cooling subsystem " \
1527  "System resources deconfigured by system due to prior error event."
1528 
1529 #define V6_EV_60_22 "Power/Cooling subsystem " \
1530  "Resource deallocation event notification."
1531 
1532 #define V6_EV_60_30 "Power/Cooling subsystem " \
1533  "Customer environmental problem has returned to normal."
1534 
1535 #define V6_EV_60_40 "Power/Cooling subsystem Concurrent Maintenance Event."
1536 
1537 #define V6_EV_60_60 "Power/Cooling subsystem Capacity Upgrade Event."
1538 
1539 #define V6_EV_60_70 "Power/Cooling subsystem Resource Sparing Event."
1540 
1541 #define V6_EV_60_80 "Power/Cooling subsystem Dynamic Reconfiguration Event."
1542 
1543 #define V6_EV_60_D0 "Power/Cooling subsystem " \
1544  "Normal system/platform shutdown or powered off."
1545 
1546 #define V6_EV_60_E0 "Power/Cooling subsystem " \
1547  "Platform powered off by user with normal shutdown."
1548 
1549 #define V6_EV_70_00 "Other subsystem Not applicable."
1550 
1551 #define V6_EV_70_01 "Other subsystem Miscellaneous, Information Only."
1552 
1553 #define V6_EV_70_08 "Other subsystem Dump Notification."
1554 
1555 #define V6_EV_70_10 "Other subsystem " \
1556  "Previously reported error has been corrected by the system."
1557 
1558 #define V6_EV_70_20 "Other subsystem " \
1559  "System resources manually deconfigured by user."
1560 
1561 #define V6_EV_70_21 "Other subsystem " \
1562  "System resources deconfigured by system due to prior error event."
1563 
1564 #define V6_EV_70_22 "Other subsystem Resource deallocation event notification."
1565 
1566 #define V6_EV_70_30 "Other subsystem " \
1567  "Customer environmental problem has returned to normal."
1568 
1569 #define V6_EV_70_40 "Other subsystem Concurrent Maintenance Event."
1570 
1571 #define V6_EV_70_60 "Other subsystem Capacity Upgrade Event."
1572 
1573 #define V6_EV_70_70 "Other subsystem Resource Sparing Event."
1574 
1575 #define V6_EV_70_80 "Other subsystem Dynamic Reconfiguration Event."
1576 
1577 #define V6_EV_70_D0 "Other subsystem " \
1578  "Normal system/platform shutdown or powered off."
1579 
1580 #define V6_EV_70_E0 "Other subsystem " \
1581  "Platform powered off by user with normal shutdown."
1582 
1583 #define V6_EV_7A_00 "Surveillance Error Not applicable."
1584 
1585 #define V6_EV_7A_01 "Surveillance Error Miscellaneous, Information Only."
1586 
1587 #define V6_EV_7A_08 "Surveillance Error Dump Notification."
1588 
1589 #define V6_EV_7A_10 "Surveillance Error " \
1590  "Previously reported error has been corrected by the system."
1591 
1592 #define V6_EV_7A_20 "Surveillance Error " \
1593  "System resources manually deconfigured by user."
1594 
1595 #define V6_EV_7A_21 "Surveillance Error " \
1596  "System resources deconfigured by system due to prior error event."
1597 
1598 #define V6_EV_7A_22 "Surveillance Error " \
1599  "Resource deallocation event notification."
1600 
1601 #define V6_EV_7A_30 "Surveillance Error " \
1602  "Customer environmental problem has returned to normal."
1603 
1604 #define V6_EV_7A_40 "Surveillance Error Concurrent Maintenance Event."
1605 
1606 #define V6_EV_7A_60 "Surveillance Error Capacity Upgrade Event."
1607 
1608 #define V6_EV_7A_70 "Surveillance Error Resource Sparing Event."
1609 
1610 #define V6_EV_7A_80 "Surveillance Error Dynamic Reconfiguration Event."
1611 
1612 #define V6_EV_7A_D0 "Surveillance Error " \
1613  "Normal system/platform shutdown or powered off."
1614 
1615 #define V6_EV_7A_E0 "Surveillance Error " \
1616  "Platform powered off by user with normal shutdown."
1617 
1618 #define V6_EV_80_00 "Platform Firmware Not applicable."
1619 
1620 #define V6_EV_80_01 "Platform Firmware Miscellaneous, Information Only."
1621 
1622 #define V6_EV_80_08 "Platform Firmware Dump Notification."
1623 
1624 #define V6_EV_80_10 "Platform Firmware " \
1625  "Previously reported error has been corrected by the system."
1626 
1627 #define V6_EV_80_20 "Platform Firmware " \
1628  "System resources manually deconfigured by user."
1629 
1630 #define V6_EV_80_21 "Platform Firmware " \
1631  "System resources deconfigured by system due to prior error event."
1632 
1633 #define V6_EV_80_22 "Platform Firmware " \
1634  "Resource deallocation event notification."
1635 
1636 #define V6_EV_80_30 "Platform Firmware " \
1637  "Customer environmental problem has returned to normal."
1638 
1639 #define V6_EV_80_40 "Platform Firmware Concurrent Maintenance Event."
1640 
1641 #define V6_EV_80_60 "Platform Firmware Capacity Upgrade Event."
1642 
1643 #define V6_EV_80_70 "Platform Firmware Resource Sparing Event."
1644 
1645 #define V6_EV_80_80 "Platform Firmware Dynamic Reconfiguration Event."
1646 
1647 #define V6_EV_80_D0 "Platform Firmware " \
1648  "Normal system/platform shutdown or powered off."
1649 
1650 #define V6_EV_80_E0 "Platform Firmware " \
1651  "Platform powered off by user with normal shutdown."
1652 
1653 #define V6_EV_90_00 "Software Not applicable."
1654 
1655 #define V6_EV_90_01 "Software Miscellaneous, Information Only."
1656 
1657 #define V6_EV_90_08 "Software Dump Notification."
1658 
1659 #define V6_EV_90_10 "Software " \
1660  "Previously reported error has been corrected by the system."
1661 
1662 #define V6_EV_90_20 "Software " \
1663  "System resources manually deconfigured by user."
1664 
1665 #define V6_EV_90_21 "Software " \
1666  "System resources deconfigured by system due to prior error event."
1667 
1668 #define V6_EV_90_22 "Software Resource deallocation event notification."
1669 
1670 #define V6_EV_90_30 "Software " \
1671  "Customer environmental problem has returned to normal."
1672 
1673 #define V6_EV_90_40 "Software Concurrent Maintenance Event."
1674 
1675 #define V6_EV_90_60 "Software Capacity Upgrade Event."
1676 
1677 #define V6_EV_90_70 "Software Resource Sparing Event."
1678 
1679 #define V6_EV_90_80 "Software Dynamic Reconfiguration Event."
1680 
1681 #define V6_EV_90_D0 "Software Normal system/platform shutdown or powered off."
1682 
1683 #define V6_EV_90_E0 "Software " \
1684  "Platform powered off by user with normal shutdown."
1685 
1686 #define V6_EV_A0_00 "External environment Not applicable."
1687 
1688 #define V6_EV_A0_01 "External environment Miscellaneous, Information Only."
1689 
1690 #define V6_EV_A0_08 "External environment Dump Notification."
1691 
1692 #define V6_EV_A0_10 "External environment " \
1693  "Previously reported error has been corrected by the system."
1694 
1695 #define V6_EV_A0_20 "External environment " \
1696  "System resources manually deconfigured by user."
1697 
1698 #define V6_EV_A0_21 "External environment " \
1699  "System resources deconfigured by system due to prior error event."
1700 
1701 #define V6_EV_A0_22 "External environment " \
1702  "Resource deallocation event notification."
1703 
1704 #define V6_EV_A0_30 "External environment " \
1705  "Customer environmental problem has returned to normal."
1706 
1707 #define V6_EV_A0_40 "External environment Concurrent Maintenance Event."
1708 
1709 #define V6_EV_A0_60 "External environment Capacity Upgrade Event."
1710 
1711 #define V6_EV_A0_70 "External environment Resource Sparing Event."
1712 
1713 #define V6_EV_A0_80 "External environment Dynamic Reconfiguration Event."
1714 
1715 #define V6_EV_A0_D0 "External environment " \
1716  "Normal system/platform shutdown or powered off."
1717 
1718 #define V6_EV_A0_E0 "External environment " \
1719  "Platform powered off by user with normal shutdown."
1720 
1721 #define V6_EV_B0_00 "Reserved Not applicable."
1722 
1723 #define V6_EV_B0_01 "Reserved Miscellaneous, Information Only."
1724 
1725 #define V6_EV_B0_08 "Reserved Dump Notification."
1726 
1727 #define V6_EV_B0_10 "Reserved " \
1728  "Previously reported error has been corrected by the system."
1729 
1730 #define V6_EV_B0_20 "Reserved System resources manually deconfigured by user."
1731 
1732 #define V6_EV_B0_21 "Reserved " \
1733  "System resources deconfigured by system due to prior error event."
1734 
1735 #define V6_EV_B0_22 "Reserved Resource deallocation event notification."
1736 
1737 #define V6_EV_B0_30 "Reserved " \
1738  "Customer environmental problem has returned to normal."
1739 
1740 #define V6_EV_B0_40 "Reserved Concurrent Maintenance Event."
1741 
1742 #define V6_EV_B0_60 "Reserved Capacity Upgrade Event."
1743 
1744 #define V6_EV_B0_70 "Reserved Resource Sparing Event."
1745 
1746 #define V6_EV_B0_80 "Reserved Dynamic Reconfiguration Event."
1747 
1748 #define V6_EV_B0_D0 "Reserved Normal system/platform shutdown or powered off."
1749 
1750 #define V6_EV_B0_E0 "Reserved " \
1751  "Platform powered off by user with normal shutdown."
1752 
1753 #endif